GB / IE - 21
Fuse: 250 V,3 A; slow action
Chime: max. 68 dB(A) (at distance of 1 m)
Monitor: 2.5” TFT,colour
Monitor resolution: 640 x 240 pixels
Line-out output: 1 Vpp / 600 Ohm
Dimensions: approx. 100 x 180 x 34 mm incl. wall bracket
Casing material: indoor station: PC, ABS;
Wall bracket: Aluminium
Weight: approx. 306 g incl. wall bracket
Relative humidity: 20 -80 %
Operating temperature: -10 °C to +50 °C
Application: indoor use only
Model: KSAFF1500150W1
Power supply: 100-240 V , 50/60 Hz, 0.6 A
Power output: 15 V , 1.5 A
Application: indoor use only
Wire cross section: 2 x 0.75 mm²
Supplied length: 15 m
Max. length: 75 m (min. 0.75 mm², copper)
The following instructions are provided for your safety and satisfaction
during operation of the device. Note that non-observance of these safety
instructions results in significant risks of accident.
If this point is not heeded life and health is endangered.
Non-observance of these instructions puts property at risk
of damage.
Optimum results will be achieved by observing these instructions.
Do not leave small children unsupervised with the device, packaging
material or small parts. Otherwise there is a risk of fatal injury due to
choking or suffocation.
Perform the connection and installation while the mains power is
disconnected! Otherwise there is a risk of fatal injury due to electric
shock.
Do not damage any gas, electricity, water or telecommunication lines
during drilling and fixing work. Otherwise there are dangers of
personal and fatal injury and fire.
Treat the cables carefully. Lay these so that they cannot be damaged
and do not present any tripping hazard. Fix the cables sufficiently. Do
not pull the cables over sharp edges and do not crush or crimp them
elsewhere. Otherwise there are dangers of personal and fatal injury
and fire.
Do not place the equipment near fire, heat or long lasting high
temperature effects of more than +50 °C. Otherwise there is a risk of
Mains adapter
Connection cable
Safety instructions
Explanation of symbols and terms used:
Danger!
Attention!
Tip:
Danger!
!
!
!
!
!
fatal injury due to fire.
Do not connect any external voltage to the connection terminals.
Otherwise there are dangers of personal and fatal injury and fire.
Plug the mains adapter for the mains power connection into the mains
socket completely. Do not touch it with wet hands. Otherwise there is a
risk of fatal injury due to electric shock.
Only operate the indoor station and the mains adapter in dry areas.
Do not expose them to dripping or splash water. Only clean the
equipment with a dry and, if necessary slightly moist, cloth. Do not
submerge the equipment in water. Otherwise there is a risk of fatal
injury due to electric shock and fire.
Do not connect any damaged device (e.g. transport damage) and
disconnect the power supply immediately in the case of damage.
Unplug the mains adapter from the mains socket. Arrange for the
damage to be repaired immediately by a specialist. Otherwise there is
a risk of fatal injury due to electric shock.
Only operate the system with 15 V DC from the supplied power
supply. Before connecting the power supply to the mains, ensure that
the mains current complies with 230 V AC, 50 Hz and is fitted with
a fuse according to local regulations.
Protect the equipment and the cables against strong magnetic or
electrical fields and against strong mechanical loads and vibrations.
Only have repairs carried out by authorised and trained qualified
personnel. Otherwise there is a risk of damage due to improper use
and invalidation of the warranty.
Observe the following points:
Protect the outdoor station as much as possible againstdirect rainfall.
Mount the outdoor station at such a height that visitors can
comfortably reach the doorbell button and that the face of the person
ringing the bell is in the field of view of the camera. Pay attention to
the height of children in doing so. The vertical detection angle of the
camera is approx. 48°.
The outdoor station is usually installed at the side of the entrance
door. Ensure that the face of the visitor standing in front of the door
can be seen on the screen. The horizontal detection angle of the
camera is approx. 64°. If necessary, use the enclosed wedge shaped
bracket to align the outdoor station.
Position the outdoor station so that no direct light falls on the lens
opening. Avoid strong backlighting behind the visitor: in this case, the
person appears darker on the image. Check the camera image before
mounting. Put the unit into operation and hold the outdoor station in
the desired place for this. If necessary, change the position until you
have found the optimum image. Remember that the position of the
sun changes.
!
!
!
!
!
!
!
!
!
!
!
Attention!
Planning the installation
Outdoor station: